Send Message
Home ProductsMulti Parameter Patient Monitor

5 Parameter Patient Monitor Pet Use Multi Parameter Monitoring System for Vet Animal Patient Monitoring Devices

Certification
China Wuxi Biomedical Technology Co., Ltd. certification
China Wuxi Biomedical Technology Co., Ltd. certification
Customer Reviews
Excelente localizador de veias, excelente serviço.

—— Adilson

ผลิตภัณฑ์ที่น่าทึ่ง มีประโยชน์มากสำหรับ MSK

—— Mrs. Wantanee

Yes. The image is very good!

—— Mr. Michael Oling

Good product!

—— Dr. WAN Chun Wai Macor

Good quality and delivery in time.

—— George

Professional service

—— Fekete

I'm Online Chat Now

5 Parameter Patient Monitor Pet Use Multi Parameter Monitoring System for Vet Animal Patient Monitoring Devices

5 Parameter Patient Monitor Pet Use Multi Parameter Monitoring System for Vet Animal Patient Monitoring Devices
5 Parameter Patient Monitor Pet Use Multi Parameter Monitoring System for Vet Animal Patient Monitoring Devices 5 Parameter Patient Monitor Pet Use Multi Parameter Monitoring System for Vet Animal Patient Monitoring Devices 5 Parameter Patient Monitor Pet Use Multi Parameter Monitoring System for Vet Animal Patient Monitoring Devices 5 Parameter Patient Monitor Pet Use Multi Parameter Monitoring System for Vet Animal Patient Monitoring Devices

Large Image :  5 Parameter Patient Monitor Pet Use Multi Parameter Monitoring System for Vet Animal Patient Monitoring Devices

Product Details:
Place of Origin: China
Brand Name: BIO
Model Number: PM-9000A+(Vet use)
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Packaging Details: Carton (39*36*31cm) 5kgs
Delivery Time: 7 working - days since getting full payment
Payment Terms: Credit card, Paypal, T/T
Supply Ability: 1000 units / month

5 Parameter Patient Monitor Pet Use Multi Parameter Monitoring System for Vet Animal Patient Monitoring Devices

Description
Multi - Parameter: ECG, NIBP, SPO2, TEMP, RESP, Printer (Optional) Screen: 12.1" High Resolution Color TFT LCD Display
Weight: 5kg Applicant: Various Pet Clinics, Pet Hospitals, Veterinary Stations And Zoos
Safty Standard: GB9706.1 Animal Accessories: Animal ECG Clip Type Cable, Animal Blood Pressure Cuffs, Animal Blood Oxygen Probe
High Light:

multiparameter patient monitor

,

patient monitoring systems

5 Parameter Patient Monitor Pet Use Multi Parameter Monitoring System for Vet Animal Patient Monitoring Devices

 

Specification

 

1 ECG Lead selection: full lead, Ⅰ, Ⅱ, Ⅲ, aVF, aVR, aVL, V1-6 chest lead display
Gain selection: ×1, ×2, ×0.25, ×0.5 four gears
Frequency: 0.5Hz—100Hz
Common mode signal rejection: greater than 70dB
Scanning speed: 12.5mm/s, 25mm/s, 50mm/s three standard files
Heart rate accuracy: ±5 beats/minute
Calibration signal: 1mV (peak value, accuracy ±3%)
ST segment detection: measuring range (-2.0mV---+2.0mV)
Use standard: in line with ANSI/AMI EC13-2002 standard
Response time: 1S
Alarm mode: sound and light alarm
Heart rate alarm preset range: (exceed the preset value alarm)
The upper limit is adjustable between 1-255 times/minute
The lower limit is adjustable between 0-254 times/minute
2 NIBP
Technology: Oscillographic Method
Measurement method: reverse measurement data is more accurate
Unit of measurement: mmHg/Kpa
Overvoltage protection: double safety protection
One measurement time: less than 45S
Pressure range in cuff: 0-250mmHg
Blood pressure measurement accuracy: ANSI/AAMI SP10-2002 standard stipulates the average error and standard deviation value
Initial inflation of cuff: 180mmHg (120mmHg for children)
Cuff subsequent inflation: original systolic blood pressure + 30mmHg
Blood pressure measurement range and error:
Systolic blood pressure 60 mmHg~250 mmHg
Average pressure 45 mmHg~235 mmHg
Diastolic blood pressure 40 mmHg~220 mmHg
Blood pressure measurement error: ±1.1KPa (±8mmHg) or ±10%, whichever is greater
Response time: 1S
Alarm mode: sound and light alarm
Alarm prediction range and error: (Alarm when exceeding the preset value)
Systolic blood pressure upper limit 1mmHg~255 mmHg
​Lower limit 0 mmHg ~255 mmHg
Diastolic blood pressure upper limit 1mmHg~255 mmHg
Lower limit 0 mmHg~254 mmHg
Alarm error: ±1 mmHg
Use standard: in line with ANSI/AAMI SP10-2002 standard
3 SPO2 Range: 0-100%
Accuracy: 1%
Resolution: 1%
Pulse frequency: 20-250 beats/min
Response time: 1S
Alarm mode: sound and light alarm
Alarm range and error: (Alarm exceeding the preset value)
Upper limit 1%~100%
Lower limit 0%~99%
4 TEMP Technology: Highly sensitive thermistor probe
Body temperature measurement range: 20℃-- 45℃
Resolution: 0.1%
Body temperature accuracy: ±1℃
Response time: 1S
Alarm mode: sound and light alarm
Alarm preset range and error: (Alarm when exceeding the preset value)
The upper limit is adjustable between 20.1℃-- 45.5℃
The lower limit is adjustable between 20℃ and 45.4℃
Alarm error: ±1℃
5 RESP Respiration rate range: 0-60 times/min
Accuracy: ±1rpm
Response time: 1S
Gain options: ×1, ×2, ×4, ×0.5 four gears
Alarm mode: sound and light alarm
Alarm preset range and error: (Alarm when exceeding the preset value)
The upper limit is adjustable between 10-100 times/minute
The upper limit is adjustable between 0-99 times/minute
Alarm error: ±1rpm
6 Printer(Optonal) Specifications: Dual-channel thermal array recorder
Printing method: real-time or event trigger recording waveform, text
Resolution: Horizontal: 400dpi / Vertical: 800dpi
Note: Date (year/month/day)/time (24 hours)
Optional wall bracket, mobile bracket, backpack
7 System

Display: 12.1 inch TFT true color LCD display

Battery (optional): LeadAcid fully sealed maintenance-free battery
Safety standard: lec601-1 (International GB9706.1)

 

Standard configuration

 

1 PM-9000+ pet version host 1 unit
2 Animal ECG Clip Type Cable 1 set
3 Animal blood pressure cuffs 1 set
4 Animal blood oxygen probe 1 set
5 Body temperature probe 1 set
6 Power code 1 set
7 Grand wire 1 set

 

Optional Configuration

 

1 Built-in rechargeable lithium battery
2 Two-channel thermal printer
3 Monitor cart/bracket/hanger

 

Feature

 

1 Adopting world-famous brand modules, with high precision, standard parameters, reliable quality and stable performance.
2 High-brightness and high-resolution 12.1-inch color TFT LCD display.
3 The body is light and strong, easy to carry.
4 Rotary shuttle operation mode, dual-purpose operation interface in Chinese and English, easy to learn, easy to use and easy to operate.
5 All-lead seven-channel simultaneous display of ECG.
6 ST segment automatic detection, arrhythmia analysis, drug concentration drop table analysis.
7 NIBP dual overvoltage protection temperature drift control and other technologies ensure accurate measurement and protect patient safety.
8 Powerful storage capacity, full-parameter trend chart data throughout the entire process, ECG waveform storage and playback, and power-off save data functions.
9 The upper and lower alarm limits can be set arbitrarily, with automatic sound and light double alarm.
10 Suitable for various mammals such as cats and dogs.
11 Anti-defibrillation, anti-interference of high-frequency electric knife.
12 Support wired and wireless networking functions, support software online upgrades.
13 Optional built-in removable lithium battery for both AC and DC power.
14 Optional built-in dual-channel thermal array recorder, real-time printing of waveforms and icons.
15 It is widely used in various pet clinics, pet hospitals, veterinary stations, and zoos.

 

5 Parameter Patient Monitor Pet Use Multi Parameter Monitoring System for Vet Animal Patient Monitoring Devices 0

 

5 Parameter Patient Monitor Pet Use Multi Parameter Monitoring System for Vet Animal Patient Monitoring Devices 1

Contact Details
Wuxi Biomedical Technology Co., Ltd.

Contact Person: Mrs. Helen Bo

Tel: 86-13382885910

Fax: 86-510-85572789

Send your inquiry directly to us (0 / 3000)